Overview: product.

The Logamax compact WS160 heat interface unit

  • The concealed solution for new-builds or as a surface-mounted solution in housing stock
  • High level of DHW convenience function up to 16 l/min
  • Optimum price-performance ratio

Centralised solution with non-centralised advantages.

Positioned at a central location in the house, heat generators and buffer cylinders provide heat for the heating circuit and domestic hot water heating in the entire building. The non-centralised water heating takes place hygienically without any problems, following the instantaneous water heating principle. To calculate the operating costs, cold-water and heat meters that can be integrated record the exact consumption.

With Buderus, you have everything from a single source. With just three pipelines to be routed per string, the installation work is kept to a minimum.

Overview: product.

The Logamax compact WS160 E heat interface unit

  • Optimal for new-builds: The installation depth of the flush-mounted cupboard is just 150 mm
  • With plate heat exchanger soldered with stainless steel as a standard feature, can be used universally
  • Flexible thanks to the modular design of the basic module for domestic hot water heating and module for mixed heating circuit or heating circuit without mixer

Centralised solution with non-centralised advantages.

Positioned at a central location in the house, heat generators and buffer cylinders provide heat for the heating circuit and domestic hot water heating in the entire building. The non-centralised water heating takes place hygienically without any problems, following the instantaneous water heating principle. To calculate the operating costs, cold-water and heat meters that can be integrated record the exact consumption.

With Buderus, you have everything from a single source. With just three pipelines to be routed per string, the installation work is kept to a minimum.

Overview: product.

The Logamax compact WS160 TE heat interface unit

  • Specially designed for replacing wall-mounted conventional boilers during renovation work
  • Narrow surface-mounted solution with flexible connections at the bottom
  • Optional supply lines can be connected from above

System: intro.

Optimal integration into Buderus heating systems.

  • System-optimised for precise interplay
  • Flexible use thanks to the modular concept for any application
  • Also suitable in four-pipe systems for systems with heat pumps

System: system accessories.

Everything from a single source.

As a system expert, Buderus offers all heating system components from a single source, such as buffer cylinders and hydraulics modules, underfloor heating systems and panel radiators.

Modules.

Logamax kompakt WS160: The modular team player.

The Logamax compact WS160 heat interface unit consists of a basic module for the domestic hot water heating and a module for the apartment's heating circuit.

Heat interface unit with module for heating circuit with mixer.

Thanks to the module for the heating circuit with mixer with an integrated high-efficiency pump, the heat interface unit is ideal for use in an underfloor heating system. There are also additional connections for a bathroom radiator.

Heat interface unit with module for a heating circuit without mixer.

For tubular radiators, a module for the heating circuit without mixer is added to the basic module – with differential pressure control valve …

...or also with return temperature limitation for the heating circuit.

Replacement module.

Narrow design for replacing wall-mounted conventional boilers for a heating circuit without mixer with differential pressure control valve and return temperature limitation – optional connection of the supply lines from above.

Basic module.

Without a heating circuit, the heat interface unit can be used as a non-centralised freshwater station for DHW supply. The basic module is therefore also suitable for four-pipe systems in bivalent systems with heat pumps.

Application: example 1.

New-build of a multi-family house.

  • Non-centralised supply of the individual residential units with domestic hot water and heating
  • Inspection obligation for legionella omitted due to the domestic hot water heating following the instantaneous water heating principle without long circulation pipes
  • Running costs for domestic hot water and heating can be assigned precisely to the respective residential units

Application: example 2.

New-build of hotels or residential homes.

  • Heat production in bivalent systems with gas-condensing systems and heat pump for meeting the energy requirements
  • Non-centralised DHW supply, Centralised heating
  • Use of the basic module as a non-centralised freshwater station

Application: example 3.

Renovation of existing multi-family houses.

  • Replacement solution as a replacement for wall-mounted conventional boilers
  • Logamax compact WS160 TE with surface-mounted housing and optional connections from above
  • Running costs for domestic hot water and heating can be assigned precisely to the respective residential units
Buderus

Not optimized for smartphones.

For a convenient experience, please open the app on your desktop computer, laptop or tablet.

Thank you.
Your Buderus Team

Buderus

Not optimized for portrait mode.

Please turn your tablet sideways in landscape mode for a convenient experience.

Thank you.
Your Buderus Team

Buderus

Not optimized for this resolution.

This app is optimized for use with a screen resolution of at least 1024 x 768 pixels.

Please open the app on a device that supports a higher resolution.

Thank you.

Your Buderus Team