Application: market environment.
Renewables system technology for residential new build.
- the housing market is under considerable pressure in some regions due to lack of space
- strong growth in the apartment block segment (4–10 units)
- statutory frameworks dictate the use of heat generators that utilize renewables

Application: project.
Renewables system technology for residential new build.
A new build in the residential sector.
The apartment block will comprise six residential units. Heat generators utilizing renewables will be installed in order to comply with the EnEv. Proprietors will receive state or regional subsidies depending on the building project’s efficiency standard.

Application: requirements.
Renewables system technology for residential new build.
Requirements:
- integration of heat generators that utilize renewables
- compliance with statutory frameworks
- protection of the building fabric and high standard of living comfort for tenants

System: standard system.
Logatherm WLW196i-14 ARE air source heat pump
- very high energy efficiency thanks to modulating operation
- space saving thanks to compact design
- includes iP module as standard

System: standard system.
Logamax plus GB182i-24 gas condensing boiler
- fully fitted at the factory
- wide modulation range of 1 : 8
- robust and durable heat exchanger with ALU plus technology
System: standard system.
Logalux PRZ buffer storage tank
- buffer storage tank developed especially for heat pumps and floor stations
- temperature-dependent return feed
- integral separating plate for improved stratification

Extension stage 1:

System: extension stage 1.
Logamax kompakt WS160 floor station
- ideal for new build thanks to low system temperatures and low installed depth
- high DHW convenience
- stainless steel brazed plate heat exchanger for universal use

System
Extension stage 2:
Heat recovery ventilation.

System: extension stage 2.
Logavent HRV156 K heat recovery ventilation unit
- space saving and flexible ceiling or wall installation
- quick installation by just one person using innovative mounting device
- very lightweight (15 kg)

System: extension stage 2.
Logavent HRV156 K heat recovery ventilation unit
- high heat recovery – up to 93 %
- equipped as standard with humidity sensor for automatic demand-dependent ventilation
- versions with summer bypass and additional CO2 sensor

System: extension stage 2.
Logavent HRV156 K heat recovery ventilation unit
System benefit:
The level of insulation can be increased in order to benefit from additional subsidies. This in turn increases the level of air tightness and minimizes the air change rate through the building envelope. The air change rate is important for both building and occupants alike. As a result, it is recommended that the standard system be supplemented with a highly efficient heat recovery ventilation unit to ensure automatic air exchange and a comfortable indoor climate.

System
Extension stage 3:
Photovoltaic system.

System: extension stage 3.
Vision 60M Style photovoltaic module
- glass/glass module with output of up to 310 Wp
- 30-year product and performance warranty
- 87 % of rated output after 30 years
Fronius Symo
inverter:
- three-phase inverter without transformer
- power category 3.0 – 20 kW
- two MPP trackers as standard
System: Extension stage 3.
Buderus Wallbox WLS11i
- Highest-quality wall box eligible for funding in a contemporary design for all Type 2 electric and hybrid cars
- Can be mounted in outdoor areas or in garages
- Vehicle electricity meter ensures that energy costs are reduced with a cheaper electricity tariff
- Available with either a 230 V or 400 V connection and charging capacity of up to 11 kW
- MyBuderus app provides a good overview and is simple to control
- Energy can be managed sustainably with a photovoltaic system, the Buderus Energy manager and the MyEnergyMaster app
System: extension stage 3.
Photovoltaic system.
System benefit:
The electricity generated by the PV system supplies the heat pump system and other electrical consumers connected to the common-area power supply. From the point of view of the building’s EnEV credentials, installing a photovoltaic system is looked upon as a positive step.
Logatherm WLW196i-14 ARE air source heat pump:
- highly efficient heat pump due to variable speed control and inverter technology
- lightweight, compact design
- convenient Logamatic HMC300 programming unit
- high efficiency pump for water circulation between the indoor and outdoor units
- internet ready with integral iP module
- modulating
Logamax plus GB182i-24 gas condensing boiler:
- 24 kW output
- covers the demand at peak load
- Buderus Titanium Line design
- wide modulation range of 1 : 8
- robust heat exchanger with ALU plus technology
Logalux PRZ buffer storage tank:
- integral lances for turbulence-free charging and discharging
- buffer storage tank developed especially for heat pumps and floor stations
- temperature sensitive return feed
- integral separating plate for improved stratification
Logamax kompakt WS160 floor station:
- modular concept for flexible use (2/4 conduits)
- mechanically controlled station
- variant with module for heating circuit with mixing valve is installed in flush mounted box
- ideal for new build thanks to low system temperatures and low installed depth
- high DHW convenience
- stainless steel brazed plate heat exchanger for universal use
- shallow flush mounted box for integration of floor station and underfloor heating circuit distributor
Logavent HRV156 K heat recovery ventilation unit:
- nominal flow rate of up to 105 m3/h
- ideal for apartments in apartment blocks with floor area of up to 90 m2
- bypass variant with automatic temperature adjustment for enhanced comfort on cool summer nights
- compact dimensions for flexible and space efficient installation below the ceiling or on the wall
- quick installation thanks to innovative mounting device and lightweight design (15 kg)
- equipped as standard with humidity sensor for automatic demand-dependent ventilation; very efficient thanks to high heat recovery rate of up to 93 %
Vision 60M Style photovoltaic module:
- optimum cell protection with glass/glass technology
- glass/glass module with output of up to 310 Wp
- 30-year product and performance warranty
- 87 % of rated output after 30 years
Fronius Symo inverter:
- three-phase inverter without transformer
- power category 3.0 – 20 kW
- 2 MPP trackers as standard
- integral datalogger and webserver









Networking.
ConnectPRO web portal
- direct networking with the customers's system
- fast fault detection and troubleshooting
- predictive resource and personnel planning


Networking.
MyDevice app
- app for flexible control of the heating system
- checking of solar thermal yield
- all the most important heating system parameters at a glance

Networking.
MyVent app
- change fan stages, set an individual 7-day program or switch to automatic, sensor-controlled, demand-dependent ventilation
- reminder message for filter replacement and information section with all relevant sensor values
- for Android and iOS

Service.
ProDelivery app.
- transparent Germany-wide shipment tracking of Buderus deliveries and returns
- information on the delivery status directly in the app without having to contact the branch by phone
- considerable time savings, flexible and convenient operation due to clear layout
- large number of additional functions such as delivery history, PDF download of delivery note, parking approval, and much more.

Service.
Design support: Logavent design tool.
- quickly configure and reliably calculate mechanical ventilation systems
- just a few clicks give you a detailed overview of materials and costs, including dimensioning information and expert mode for sizing to meet specific requirements
- free online tool for PC and tablet

Service.
24/7 customer service.
- assistance with commissioning, maintenance, repair, water analysis and efficiency
- more than 300 service technicians are on call every day throughout Germany
- over 220 service products: available throughout Germany; can be combined as required